1-200 MHz return path filter

Article number: 383900

Product description:

Return path filter

The return path filter is used to bypass amplifiers in a normal coax based TV network on the data frequency of EoC. This allows the data to have a return path and the TV signal to be amplified.

  • Return path 1...200 MHz – no amplification
  • To amplifier 300...862 MHz


 

Specifications

ORDER INFORMATION
EAN Number 5702663839007
CHARACTERISTICS
Isolation TV IN Amp. - TV OUT Amp. > 49.0 (250...862MHz) dB
FREQUENCY
Frequency Range G.hn 1...200 MHz
Frequency Range TV 300...862 MHz
LOSS
Through Loss TV/EoC IN - TV/EoC OUT < 3,0(2...200MHz) dB
Through Loss TV EoC IN - TV OUT Amp. < 1,5(250...862MHz) dB
Through Loss TV EoC IN Amp. - TV/EoC OUT < 1,5(250...862MHz) dB
RETURN LOSS
Return Loss > 10,0 dB
ELECTRICAL
Impedance 75 Ω
OPERATIONAL
DC Passthrough NO
Temperature - operating -10...40 °C
Temperature - storage -20 ..70 °C
Humidity - operating 20...80 %
Humidity - storage 10...90 %
MECHANICAL
Main material Plastic housing ABS
Colour White
Packing QTY 1
Packaging Height 0,064 m
Packaging Width 0,076 m
Packaging Depth 0,096 m
Net Weight 0,124 kg
Tara Weight 0,019 kg
Total Weight 0,143 kg